For Your
Safety
If You Smell Gas
1.
SHUT OFF gas to appliance
2. Extinguish ANY open flame
3. If odor continues, IMMEDIATELY call gas supplier
For
Your Safety
Do
not store or use gasoline or any
other flammable vapors and liquids
in the vicinity of this, or any other
appliance
This lantern
must be installed by a certified plumber to conform to local codes or
in absence of local codes conform to the national fuel gas code ANSI Z223.1-1984.
Installation
shall be in accordance with CAN1-B149.1, installation code natural gas
burning appliances and equipment.
Threaded
parts and screws conform to CSA standard for unified screw threads B1.1,
and unified inch screw threads ANSI/ASME B1.1.
Attention
Installers: leave instructions with appliance so consumer will retain
them for future reference.
Installation
instructions for: Wall mount and Yoke mount lanterns.
Note:
The minimum clearance from combustible construction is 12" at top
and 6" at the sides.
1. Using
the mounting holes in the bracket as a template mark and install the ¼"
X 4" hanger bolts (supplied). If mounting on brick, masonry-anchors
will need to be used (not supplied).
2. Reduce gas supply line from exterior wall/ceiling to ¼"
copper utilizing flare fittings only.
3. Make a copper coil using ¼" O.D. copper tubing to allow
hook-up to gas supply line to ¼" flare fitting located in
wall or ceiling mounting box of lantern. All hook-ups must be made within
the width, depth and height of lantern mounting box.
4. Assemble the mount to the lantern.
5. Check for any leaks using soap solution. If air bubbles appear, shut-off
main gas line and tighten all fittings. Warning: Never use open flame
to check for leaks.
6. Secure the lantern to the wall or ceiling.
Installation
Instructions for: Post Mount Lanterns
Note:
The minimum clearance from combustible construction is 12" at top
and 6" at the sides.
1. Select a suitable post for mounting. If a Legendary Lighting unit is
not used, ensure that your post is sufficiently stable to support the
lanterns weight, and that it is firmly set in its foundation to maintain
stability.
2. Configure the gas supply line with the appropriate fitting to attach
to ¼" flare nut. Gas line must be able to move up and down
so lantern will slide down on mounting bracket. This can be accomplished
by coiling the line in the post.
3. Assemble the mount to the lantern.
4. Check for any leaks using soap solution, if air bubbles appear, shut-off
main gas line and tighten all fittings. Do not check using open flame.
5. Slide the lantern down onto the post and position in the correct orientation.
6. When attaching mounting bracket to top of column use brass or rust
resistant #10 hex head self-tapping sheet metal screws.
Propane
Lantern: If your lantern is a propane version it will be equipped
with a propane burner and LP regulator.
Lighting
Instructions:
· Automatic Shut-off Equipped
1. Open lantern door and turn the valve clockwise.
2. Locate and depress the plunger valve located in the mounting bracket.
3. Using flame from match or lighter, hold flame over tip of burner.
4. Continue to hold the plunger valve down for 60 seconds to allow the
thermocouple to heat up and remain open. If the flame is extinguished
repeat steps 2 & 3.
5. Adjust flame by turning valve to desired position. Bottom of flame
should not leave top of burner tip for optimum appearance and wind resistance.
6. Adjust the thermocouple so the tip is impinged in the flame.
· Electronic Ignition Equipped
1. Open lantern door and turn the valve clockwise.
2. Energize the light by turning on the switch. See attached Electronic
Ignition Installation Procedures.
Maintenance
Instructions:
1. Check
regularly to ensure that appliance area is free of combustible materials.
Gasoline or other flammable vapors or liquids should not be stored near
lantern.
2. Nothing should obstruct the flow of combustion or ventilation air.
3. Occasionally the glass will need to be cleaned with household glass
cleaner. Turn lantern off and allow to cool before cleaning glass. Burner
tip should be visually checked for condition and clean deposits from orifice
slot if necessary.
Note:
should you need technical assistance please call 800-350-5361
Legendary
Lighting, 1016 N. Flowood Drive, Flowood, Mississippi 39232,
Shop Gas Lighting
|